ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec, Version 2.1.2 Copyright Arcada Software, Inc. 1995. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ This file contains important technical information about your program. To print this file, type COPY README.TXT PRN at the DOS prompt. The following subjects are discussed: 1. Installation 2. Memory Requirements 3. Verify Your First Backup 4. Tape Despooling 5. Compatibility Test Failure 6. Running Conner Backup Exec under DesqView 7. Compressed Drives 8. Installing Conner Backup Exec on a System with Stacker 9. The DOS Append Command 10. Setup File Compatibility with Conner Backup Exec for Windows 11. Hardware Compression Not Supported 12. Power Management Conflicts 13. Parallel Port Drive Configuration 14. IRQ Conflicts 15. Maximum Parallel Port Cable Length 16. Potential Conflict with PC-DOS 6.1 RAMBOOST 17. Encrypted Backup Sets 18. Backing Up Large Numbers of Files to AccuTrak Tapes 19. NetWare Server Information and AccuTrak Tapes 20. NetWare Files With an Execute Only (X) Attribute 21. Files Not Backed Up 22. Formatting Tapes on 386 Machines 23. Tape Format Incompatibilities 24. 3020 Drive Requirements 25. Controller Conflicts ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 1. Installation ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec for DOS will not install or operate correctly from a DOS box within Windows. It must be installed and operated directly from the DOS prompt. This program works best when both the BUFFERS and FILES statements in your CONFIG.SYS file are set to at least 30. This program must have a FILES setting of at least 10 and a BUFFERS setting of at least 15 to run efficiently. NOTE: If you are using other software that requires a lower buffers setting, you should manually adjust the buffers setting. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 2. Memory Requirements ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec for DOS requires at least 512K of free memory; however, this software runs faster if more memory is available. To check your free memory, type MEM at the MS-DOS prompt. To free memory, remove any TSRs before running Conner Backup Exec. See your system documentation for other methods. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 3. Verify Your First Backup ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ When you make your first backup with Conner Backup Exec, it is highly recommended that you use the Read and Compare option. During the Compare phase, Conner Backup Exec compares each file on the tape with the original on your hard drive to ensure that they are identical. While comparing will increase the time of the backup, it will confirm that your computer system, tape drive, and Conner Backup Exec are working together correctly. If compare fails, run a hard disk utility program to determine whether the hard drive is free of errors and try the backup again. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 4. Tape Despooling ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If a tape "despools" (comes loose from the cartridge capstan, a very rare occurrence), it may be necessary to turn the drive's power off and on again or to reboot your system to clear the drive. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 5. Compatibility Test Failure ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ The compatibility test consists of a small backup and compare, automatically performed by Conner Backup Exec to verify that reliable backups can be performed with your current configuration. The most common cause of compatibility test failure is DMA error. Therefore, when the compatibility test fails, Conner Backup Exec automatically resets the DMA (Direct Memory Access) to Low Speed. During installation, other factors may contribute to compatibility test failure. For this reason, the following procedure is recommended if the compatibility test fails during installation: 1. Complete the installation 2. Restart Conner Backup Exec 3. Choose Configure 4. Choose Configuration Tests 5. Set the Direct Memory Access to High Speed 6. Redo the compatibility test If the compatibility test fails again, follow the guidelines presented in the on-line help, available by pressing F1. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 6. Running Conner Backup Exec under DesqView ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ To run Conner Backup Exec under DesqView, make the following selections in DesqView: ù Create an entry in the Program Menu for Conner Backup Exec. ù Under Advanced Options, specify that Conner Backup Exec cannot share CPU when in the foreground, and that it cannot run in the background. ù Select Uses Its Own Colors. ù Set the Memory Size option to 512 K. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 7. Compressed Drives ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If you are using compression software such as Stacker or DoubleSpace, do not back up the compressed file, back up the logical drive instead. Because these compressed files are typically very large, attempting to restore may cause problems if you do not have enough disk space to restore the compressed file. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 8. Installing Conner Backup Exec on a System with Stacker ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If you have Stacker software installed on your computer, you may not want to let Conner Backup Exec make changes to your AUTOEXEC.BAT file. Some versions of Stacker create their own AUTOEXEC.BAT file which should not be modified, and it is this file that Conner Backup Exec will find. You can tell if this is the case on your computer if, during Conner Backup Exec installation, the AUTOEXEC.BAT file that is displayed says "DO NOT MODIFY THIS FILE." In this case, you will need to find your original AUTOEXEC.BAT file and make the following changes: ù Add the Conner Backup Exec directory to your PATH statement. ù Add the command "SET QBACKUP=path_name" where path_name is the directory you want Conner Backup Exec to use for setup and catalog files ù If you want to load the Backup Scheduler each time you start your computer, add the command QSCHED as the last command in your AUTOEXEC.BAT file. For more information on loading the Backup Scheduler, see the help topic "Installing the Backup Scheduler TSR." ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 9. The DOS Append Command ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If you use the DOS Append command with the /X or /X:ON option, when you perform a restore, some files may not be restored. This is because of the way DOS reports names of existing files when this command is in effect. It is highly recommended that you deactivate the Append /x command before performing restores. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 10. Setup File Compatibility with Conner Backup Exec for Windows ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec for Windows, version 2.1.2, can read, use, and modify setup files created by Conner Backup Exec for DOS, version 2.1.2. If you have made individual file or directory selections in a setup file that is opened and resaved by Conner Backup Exec for Windows, you may notice that some filenames and directory names are displayed in a different color (red if default colors are used). This display change will not affect the selections. Conner Backup Exec for DOS, version 2.1.2, can use setup files created by Conner Backup Exec for Windows, version 2.1.2, with the following limitation: Individual file and/or directory selections made with the keyboard or mouse will not transfer from the Windows setup file to the DOS setup file. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 11. Hardware Compression Not Supported ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec for DOS, Version 2.1.2, does not support the hardware compression function found on some high-speed controller cards. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 12. Power Management Conflicts ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Some Desktop computer systems and laptops have power management systems that take a "snapshot" of RAM and store it on the hard drive when they power down. This may create a conflict if it occurs during a backup or restore or a tape formatting operation. When using Conner Backup Exec, it is recommended that you turn OFF all power management features. If you're using a laptop, avoid running power management features by using an outlet rather than batteries. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 13. Parallel Port Drive Configuration ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If your parallel port tape drive does not automatically configure, first ensure that the power to the drive is on. If it is, turn it off, then on, and try configuring it again. See below for more suggestions. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 14. IRQ Conflicts ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ You may experience a conflict in IRQ selection if you are configuring a parallel port tape drive on a system that includes a sound card. SoundBlaster cards and compatibles use a default IRQ of 7, which is also used by a printer port (LPT1). If this conflict occurs, you can: * Change your sound card's IRQ if possible. Some cards do not allow this change and some games may not work correctly. * Check your system documentation to see if your parallel port can be configured to use a different interrupt. Devices that may conflict with printer port interrupt: Sound Cards Scanner Cards Network Cards Bus Mice Other printer ports Other devices IRQ usage can be determined by using the Microsoft Diagnostics Program. Exit Windows and type MSD at the DOS prompt. Note that MSD cannot always diagnose printer port IRQ conflicts. Printing does not require a hardware interrupt and will function normally even if an interrupt conflict exists. Symptoms of an IRQ conflict include Conner Backup Exec not finding the tape controller and network problems when backing up to tape. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 15. Maximum Parallel Port Cable Length ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Your parallel port tape drive should be connected directly to your system's parallel port. If you use the pass-through connector on the drive to connect a second device such as a printer, the maximum cable length for both devices is approximately 10 feet (3 meters). If you have difficulty using your tape drive when a second device is connected to the pass-through connector, disconnect the second device and its cable while using the tape drive. If you experience data loss when using a printer connected to the pass-through connector, shorten the printer's cable if possible or disconnect the tape drive while printing. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 16. Potential Conflict with PC-DOS 6.1 RAMBOOST ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If you wish to use the Scheduler TSR, QSCHED.COM, with PC-DOS 6.1's RAMBOOST device, you must use the /SKIPHIGH switch to load it in conventional memory. Type QSCHED.COM /SKIPHIGH at the command line or include it in your AUTOEXEC.BAT line. NOTE: The QSCHED.COM TSR must be loaded last. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 17. Encrypted Backup Sets ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec cannot restore backup sets encrypted by other backup programs. You must use the original software to restore them. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 18. Backing Up Large Numbers of Files to AccuTrak Tapes ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ When using AccuTrak tapes, backing up a very large number of files--approximately 30,000 to an 80MB tape or 45,000 to a 120MB tape--will result in an error. Divide the files into two or more backup sets and back up each set to its own tape. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 19. NetWare Server Information and AccuTrak Tapes ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Because of the proprietary format used by the tapes, NetWare bindery files, trustee information, and extended attributes cannot be backed up to AccuTrak tapes. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 20. NetWare Files With an Execute Only (X) Attribute ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ NetWare files with an execute only (X) attribute will not be backed up, compared, or overwritten during a restore. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 21. Files Not Backed Up ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec does not log or back up a number of files to avoid potential system conflicts if they are restored. Compressed Volume files: DBLSPACE.0?? DRVSPACE.0?? STACVOL.* Windows swap files: 386SPART.PAR WIN386.SWP NetWare System files: BACKOUT.TTS NET$SPL.QUE NET$MSG.SYS DIRSTAMP.SYS NET$OBJ.SYS* NET$PROP.SYS* NET$VAL.SYS* NET$BIND.SYS* NET$BVAL.SYS* SYS$LOG.ERR * These NetWare bindery files will be backed up or restored only if you are logged on to a server as Supervisor. See your User Guide for more information. Additionally, Conner Backup Exec will not back up a number of temporary files used by the program when these files are found in the program's directory. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 22. Formatting Tapes on 386 Machines ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ If you encounter difficulties formatting tapes on a slower 386 machine or receive a message stating "The tape controller is not responding correctly," make sure your turbo switch is on. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 23. Tape Format Incompatibilities ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Conner Backup Exec cannot format AccuTrak tapes. If your drive supports AccuTrak tapes, you should purchase them preformatted. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 24. 3020 Drive Requirements ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ To achieve optimal performance with a 3020 drive, a 1Mbit controller or higher (2Mbit) is required. ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ 25. Controller Conflicts ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ The Promise 2300 EIDE VLB controller must run in fast mode (/f parameter) in order to work with floppy tape drives.