Descriptions - For the Diagnostic Program ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Siemens OfficeLAN PCI 10/100 TX Fast Ethernet Adapter Diagnostic Program INSTALLATION GUIDE (1). History : -------------- Version Descriptions --------- ------------------------------------------------------------ v2.11 Release to support the 10Base-T/100Base-TX media types. v2.14 Update to support the MII Phy with N-Way Auto-Negotiation capability. v2.15 Update to decrease the time to wait for N-Way Auto-Negotiation complete during reset. v2.16 Update to support PCI device rev.3A controller. v2.17 Modify the copyright message of the Diagnostic Program. v2.18 Modify the text messages of the Diagnostic Program. (2). Software Environment : --------------------------- 1. Make sure that free conventional memory is more than 200K before execute this Diagnostic Program. 2. Make sure that Expanded Memory Manager (EMM386.EXE) is version 4.49 or later (date is 05-31-94) for compatibility. 3. The Diagnostic Program should not be run under DOS prompt of Windows. (3). Statistic Counters : ------------------------- 1. Transmission: Items Descriptions ---------------------- ------------------------------------------- Collision Count Number of collisions before the frame is transmitted. Frame deferred When set, frame was delayed to be transmitted because of the carrier was asserted. FIFO underflow When set, transmission was aborted because the transmit FIFO is underflow. It may be caused by PCI bus overloaded or low threshold in the transmit FIFO. Heartbeat failure When set, it means SQE test fails. Excessive collisions When set, transmission was aborted because of 16 consecutive collisions. Late collision When set, the controller has run into a collision after the collision window of 64 bytes. No carrier When set, carrier is not present during the transmission. Loss of carrier When set, carrier is lost during the transmission. Jabber time-out When set, the transmit jabber timer expired The controller's transmitter is babbling. Retry count Indicates the number of retry for Client station to re-build connection with Server station when timeout to wait for response from Server station. 2. Reception: Items Descriptions ---------------------- ------------------------------------------- FIFO overflow When set, the receive FIFO is full. The controller flushes the receive FIFO and closes the descriptor with this bit set. The frame is truncated. CRC error When set, cyclic redundancy check failed. Dribbling bit When set, the received frame is not a integer multiple byte frame. This bit is reported only if the dribbling bits are more than 2 bits. Watchdog time-out When the controller receives a frame longer than 2048 bytes, the controller set this bit. Collision seen When set, a late collision after the collision window has happened during receiving of the frame. Frame too long When set, the received frame is longer than the maximum Ethernet-specified length 1518 bytes. Runt Packet When set, the received frame is corrupted by premature termination before the collision window had passed. Length error If the controller detects an unavailable buffer when it pre-fetches the next descriptor, the controller truncates the frame and set this bit.