Server Driver for NetWare 4.X

   Introduction:
   -------------
   This document describes the procedure to install the NetWare v4.X
   server driver for PCI ethernet adapter.

   Location of Driver:     \NWSERVER\4X\PCISRV.LAN

   Installation Procedure :
   ---------------------
      Before you start with the installation  process,  make sure that
      the Novell NetWare v4.X server is properly installed.
      Similarly, your adapter should also be properly installed in your
      server.
      1. Insert the ETHPCI Driver Diskette into drive A and check the
         contents of subdirectory \NWSERVER\4X, It should contain the
         following file :

         PCISRV.LANÄÄÄ  Novell NetWare V4.X Server Driver
         PCISRV.LDIÄÄÄ  Novell NetWare V4.X Server Driver Installation
                        Information File

      2. At the  NetWare prompt (indicated by the Server name), run the
         INSTALL.NLM program by typing:

         server name: LOAD INSTALL <Enter>

      3. Select " Driver Option " and press <Enter>.

      4. Select  " Configure network drivers "  and press
         <Enter>.

      5. Select " Select a driver " and press <ENTER>.

      6. Press the <Ins> key to specify other drivers to install.

      7. Press  <F3>  and specify the driver path (A:\NWSERVER\4X)
         and press <Enter>.

      8. The PCISRV.LAN driver should appear in your choice list for the
         'Select a  LAN  Driver' field. Choose this  driver to start the
         driver loading and  binding  procedure.  This will allow you to
         load and bind all 4 frame types supported by NetWare.

      9. Add the LOAD and BIND statements you require to the server's
         AUTOEXEC.NCF file so that the LAN driver will load automatically
         each time the server starts up.


      Installation Notes:
      -------------------
      1. Installing Multiple LAN Adapters:
         The keyword "EtherID" is the ethernet address of a adapter. This
         keyword is provided for multiple LAN adapters in a single server
         by the driver PCISRV.LAN.  So, add EtherID in LOAD commands. For
         example:

         LOAD PCISRV EtherID=004005678901 FRAME=Ethernet_802.2 NAME=LAN_A
         BIND IPX TO LAN_A NET=11
         LOAD PCISRV EtherID=004005678902 FRAME=Ethernet_802.3 NAME=LAN_B
         BIND IPX TO LAN_B NET=22

      2. The default frame type for NetWare 4.X binding is Ethernet_802.2
         and not Ethernet_802.3. This is the difference between v3.11 and
         v4.X of NetWare operating system.

      3. Edit the AUTOEXEC.NCF if you want to change some parameters.
         For example,  if you're using a  NetWare  3.11  workstation  and
         wants to log into a NetWare v4.X server. The default frame type
         of NetWare 3.11 is Ethernet 802.3, while that of NetWare v4.X is
         Ethernet  802.2.  Before you can log into the NetWare v4.X, make
         sure  there  is  a protocol  binding for  Ethernet  802.3 in the
         server's AUTOEXEC.NCF file.

   If problems occur during the binding process, your  screen will prompt
   you with error  messages.  Please refer to your NetWare 386 manual for
   details on these messages.